Approaches to surgical operation are changing and evolving mostly because of major technological advancements that are being made in various fields including surgical medicine. Single incision laparoscopic surgery is often referred to using the abbreviation SILS, but it also has many other names. Among the names SILS goes by are Single-port laparoscopy, single-port access surgery (SPA), Single-access endoscopic surgery (SAES), and single-port incisionnless conventional equipment-using surgery (SPICES). Other names include natural-orifice trannsumbilical surgery (NOTUS), one-port umbilical surgery (OPUS), and laparo-endoscopic singular-site surgery (LESS).

SILS as a technique in laparoscopic surgery is still relatively new because it was only developed recently. Because this method utilizes a single entry point into the body, it is referred to as minimally invasive. The navel is the major entry point used on most patients. Only a small scar remains after the process has been done, which is one of the reasons why this process is preferred by many people.

Entry points are either 11mm or 22 mm incisions. One incision is utilized to minimize scarring and pain felt during and after the process. The use of one incision is opposed to the traditional laparoscopic procedure that uses multiple entry points. There are some of the most highly qualified specialists in SILS in New York. Therefore, it is quite advisable to consider visiting the city when in search of specialists in this process.

There are two categories of specialized surgical equipment used by SILS. The two broad categories are hand instruments and access ports instruments. Access ports instruments are of various types including the GelPOINT system, QuadPort+, TriPort15, Uni-X, SILS device, and TriPort+. The manufacturers of these instruments are different.

Conversely, there are three key configurations of hand instruments in use. They include articulating, pre-bent rigid, and standard configurations. It has taken over the past thirty years to develop standard hand tools. They are made with rigid design. The SPL reduced triangulation instrument problem was solved by the development of articulation hand instruments.

The choice of whether or not to use articulating or standard instruments usually lies with the surgeons. There are a few factors that influence the decision. Among these influential factors are access port used, cost, and surgical skills of a surgeon. Articulating instruments are very costly when compared to standard instruments. This procedure is made safer and more effective by the use of specialized instruments.

The degree of awareness of SILS among surgeons is very high. However, the performance of SILS is limited to a few surgeons owing to its high level of complexity, limited space of access, and the use of specialized instruments. Surgical doctors who perform the procedure have to be highly skills and trained in surgical processes. That has promoted negative perception from the public and limited indulgence in the process.

SILS has been used on a wide variety of surgical procedures. Some major examples include colectomy, sleeve gastrectomy, adjustable gastric banding, sacrocolpopexy, hysterectomy, appendectomy, and nephrectomy among several others. Among European countries and the United States, standard instruments are being used more commonly compared to specialized instruments.